PTAC Packaged Terminal Air Conditioners & Heat Pumps
PTAC Installation Recommendations PTAC units should be installed no closer than 12" apart when two units are side by side. If three or more PTAC units are to operate next to one another allow a minimum of 36" between units. Also, a vertical clearance of 60" should be maintained between units installed. In the interior of the room the unit should be[PDF]
Installation, Operation, and Maintenance - Trane
8 PTAC-SVX0 02A-EN Unit Features This unit has many features that are different from those found on standard PTAC models. The owner should become familiar with these features in order to fully understand the operation and capabilities of the unit: Intelligence The unit has an on board computer which utilizes real-time diagnostics to prolong the
Ecobee3 Lite SmartThermostat, Black - - Amazon
Thermostat + Smart Thermostat Voice Control : Power Source AC/DC : Voltage 24 Volts : Item Package Quantity 1 : Display Style Touchscreen : Mounting Type Mounting plate and screws : Included Components Ecobee3 lite thermostat, power extender kit, hardware pack, instructions, wire labels, mounting plate, trim plate
Emerson Sensi Wi-Fi Smart Thermostat for Smart Home, DIY,
Decided to replace my 17-year old RobertShaw thermostat (t-stat) because I wanted remote capability. I was hesitant to touch A/C wiring whereas I had no experience with A/C wiring. The A/C company wanted $90 to install it, but I decided to do it myself since it was just a 4-wire system. (no c-wire).[PDF]
Amana PTAC Owners Manual and Installation Instructions
setback does not work with a wired remote thermostat. Door Switch and Motion Sensor Low V oltage Terminals (IN1, IN2, COM) - The door switch and motion sensor operate as a unit, the terminals allow for wired connection of a door sensor to the control board. The motion sensor interprets any door movement as a signal of occupancy. If the switch
Furnace Short Cycling with Nest Thermostat - Ryan Duell
Jan 07, 2014Occasionally when I would walk by the thermostat it would say that the wiring had changed. I would hit continue and then done and the message would go away only to return again later. I called their support line and after sitting on hold for 43 minutes I was connected to a very helpful technician. She had me disconnect the C or common wire.
YMGI Group : The Best Value in State-of-the-Art HVAC
YMGI State-of-the-Art Heating and Cooling. YMGI VRF Outdoor modular top discharge 6, 8 & 10-ton modular systemsiple units can be configured together for a capacity up to 30 tons. Ultra Heating: 80% capacity at -22°F ambient temperature.; Heat Recovery: Heat and cool simultaneously.; Solar Series: PV assisted high efficiency heating and cooling. Qualifies for
Bosch 4 Ton Heat Pump Inverter System 2.0 Series 20 SEER
Bosch 2.0 Series 4 Ton True Inverter Heat Pump System Delivers 20 SEER Efficiency While Keeping Sound Levels As Low As 56dBA. The Outdoor Compressor & Fan Motor Freely Ramps Up & Down Per Demand, Offering Operating Levels From 25-110% Capacity. 10 Year Parts Warranty & 90 Day Labor Warranty!
Bosch 2-3 Ton Heat Pump 2.0 Inverter Condenser, BOVA-36HDN1-M20G
Bosch 2.0 inverter heat pump condenser delivers 20 SEER efficiency while keeping sound levels to a minimum. The compressor & motor can freely ramp up & down per demand, offering operating levels from 25-110% & as quiet as 56dB. Your BOVA-36HDN1M-20G monitors room temperature, humidity and refrigerant levels at all time
Actron AC Error Codes and Troubleshooting
Mar 22, 2021Check thermostat settings are correct. Check thermostat set point is low enough for cooling or high enough for heating. Check the Master Controller is set to the correct mode for COOL/AUTO/HEAT. Conditions: Air does not flow. Remedy: Check if the unit is set in the correct mode COOL/AUTO/HEAT. Check your zone control is turned on.